Model NO.: GC5890N
Weight: 70kg
Furnace Dimension: 28*30*18cm
Package Size: 61*61*78cm
Production Time: 7days
Shipping Time: 7-15days
Trademark: Kejie
Transport Package: Wooden
Specification: 67*53*49cm
Origin: China
Model NO.: GC5890N
Weight: 70kg
Furnace Dimension: 28*30*18cm
Package Size: 61*61*78cm
Production Time: 7days
Shipping Time: 7-15days
Trademark: Kejie
Transport Package: Wooden
Specification: 67*53*49cm
Origin: China
Gas Chromatography Analysis/ High Accuracy and Precision Lab Equipment Instrument

Professional Gas Chromatograph for Ethylene Oxide

.Instruction
The special GC for ethylene oxide is your best choice in GC industry. It is equipped with the special chromatography column and headspace injector, which can analyze the ethylene oxide residue precisely. 

Features
4.1 The detecting method is professional, innovative and adapted to the new international standards.
It Installs headspace injector of DK-300A to save the time for pre-processing of the injections, avoid the interference caused by organic solvents for analysis, and reduce the contamination of the column and inlet, reaching high analysis efficiency. The special chromatographic column successfully solves the overload problem of the columns and detectors. The changing of balance temperature, insulation temperature, injecting time and inflation pressure can be set.
 
4.2 The system is high precise and multi-functional, while its operation interface is simple and humanized.
4.2.1The use of new integrated digital electronic circuit has stable and reliable performance, and the temperature control can be precise to 0.01ºC.
4.2.2 It has functions of boot self-diagnosis, stopwatch(convenient to detect flow), timer operation, storage protection for power off, keyboard locking, anti-interference for power mutation, network data communication and remote control. All these functions are simple to operate.

 
4.3 Improved uniqueness and selectivity of the injector system with various injecting ways.
4.3.1 The unique inlet design solves the injecting discrimination, while the dual-column compensation function not only solve the problem of program drift by heating, and minus the effects of background noise, so as to get the minimum LOD.
4.3.2 Installed two kinds of injectors: packed column injector, split/splitless capillary injector(with the function of diaphragm cleaning). 


4.4 Good stability and high sensitivity of the detector and its perfect supporting facilities can satisfy your various detection requirements.
It is convenient and time-saving, while the injectors can get high sensitivity, precise results and less error by using FID, headspace injecting method and the special chromatographic column for ethylene oxide.
 
4.5 Improved column designation for precisely controlling the programmed heating and furnace temperature, with the features of stability, balance and time-saving.
4.5.1 Increased column volume, and the intelligent backdoor system largely shortens the time for detector to keep stable and balance after the programmed heating/cooling.
4.5.2 Heating furnace temperature ramp range: environmental temperature +5ºC~420ºC.
4.5.3 7 steps programmed heating and the heating rate is 0.1~120ºC/min.
4.5.4 You can re-calibrate the furnace temperature, and set the maximum temperature within 420ºC according to your needs for the balance time of the heating furnace temperature.


.Parameters
Column oven
Furnace dimensions 28 x 30 x 18cm
Temperature range Room temperature +5~420ºC
Temperature setting 1ËšC, programmed heating rate 0.1ËšC
Maximum heating speed 120ºC/min
Temperature stability it will be 0.01ËšC, when the environmental temperature changes 1ËšC.
Programmed heating 7 steps
Programmed heating rate 0.1-120ºC/min(increment of 0.1ºC)
Column loss can be compensated (dual channel column)
FID
Maximum operating temperature 400ºC
LOD ≤5 x 10-12g/s[n-C16]
Drift ≤5 x 10-13A/min
Noise ≤2 x 10-15A
Linear dynamic range ≥107

.Application fields
It is widely used in the fields of petroleum, chemical, food, pharmaceutical, environmental protection, disease control, safety supervision, water, electricity, metallurgy, scientific research and QC.

.Detail pictures
Gas Chromatography Analysis/ High Accuracy and Precision Lab Equipment Instrument

HD LCD screen display, clear and could protect the eyes
Gas Chromatography Analysis/ High Accuracy and Precision Lab Equipment Instrument
You
 can choose different detectors, for example FID/TCD/FPD/ECD/NPD
Gas Chromatography Analysis/ High Accuracy and Precision Lab Equipment Instrument


·
Packing&Shipping
(1)Standard export wooden case with high quality cushioning material ensure the item arrive customer in good condition.
(2)Carefully check every packing detail before delivery to avoid any troubles during the transportation.
(3)Appointed logistics company could be used according to customers demands.
(4)Do our best to make sure customer can get their goods in time.

Gas Chromatography Analysis/ High Accuracy and Precision Lab Equipment Instrument


·About Kejie Group
Nanjing Kejie Group have one researching institution and four professional production bases,which is a leading manufacturer in R&D, manufacturing and sales of gas chromatography, high efficient liquid chromatography, atomic absorption spectrometer, atomic fluorescence, UV visible spectrophotometer, headspace injector and other analytical instruments and related products.

Gas Chromatography Analysis/ High Accuracy and Precision Lab Equipment Instrument


·Our Service
Our commitment to you doesn't end when your equipment is shipped-It begins.
1,One years'warranty supported by product experts
2,AMC,post warranty,24H/7D response
3,Lifetime's spare parts supply for our products
4,Long term distribution partners worldwide ensure individual on-site customer consultation and service.

·Contact Information
Address:
2nd floor, A1 building, Nanjing University of Sci&Tech,
No.129-3 Guanghua Road, Nanjing City,
Jiangsu Province, China
Postal Code: 210014

.Sales Contact
Tel: 86-0731-84135155  
FAX: 86-0731-89833299
 
 

Please feel free to submit your inquiry information to us.We will contact with you as soon as possible.


·FAQ
Q1: Are you the factory?
A1: Of course we are,we have one Researching Institution and four Professional Production Bases
 
Q2:What's the warranty period? How do you provide this?
A2:Two years (24 month).
We have very strict inspection, the instruments which you received is high-quality and reliable.
If there's any error, we'll provide you the on line solution with in 12 hours. We'll provide you the spare parts and the shipping cost totally free.
If the problem was caused by the instrument quality, and cannot be repaired, we'll ship you the new one.
 
Q3:What's the production time?
A3:Usually 20 days for production, some equipment need extra time to debug.
 
Q4:What's the Dlivery method ?

A4:Light-weight cargo is usually by express , Air transport and sea shipping is acceptable (provide with safty packing)
 
Q5:What's the delivery time?
A5:According to different method and country , express will be 6~15 days
 
Q6:How to install and operate?
A6:According to each instruction manual which sent with equipment. ( We also provide after-sale technical support)
 
Q7:What's the payment term?
A7:Usually we do 50%TT deposit ,50%TT balance before shipping.Western Union, are acceptable.


  Gas Chromatography Analysis/ High Accuracy and Precision Lab Equipment Instrument

Professional Gas Chromatograph for Ethylene Oxide

.Instruction
The special GC for ethylene oxide is your best choice in GC industry. It is equipped with the special chromatography column and headspace injector, which can analyze the ethylene oxide residue precisely. 

Features
4.1 The detecting method is professional, innovative and adapted to the new international standards.
It Installs headspace injector of DK-300A to save the time for pre-processing of the injections, avoid the interference caused by organic solvents for analysis, and reduce the contamination of the column and inlet, reaching high analysis efficiency. The special chromatographic column successfully solves the overload problem of the columns and detectors. The changing of balance temperature, insulation temperature, injecting time and inflation pressure can be set.
 
4.2 The system is high precise and multi-functional, while its operation interface is simple and humanized.
4.2.1The use of new integrated digital electronic circuit has stable and reliable performance, and the temperature control can be precise to 0.01ºC.
4.2.2 It has functions of boot self-diagnosis, stopwatch(convenient to detect flow), timer operation, storage protection for power off, keyboard locking, anti-interference for power mutation, network data communication and remote control. All these functions are simple to operate.

 
4.3 Improved uniqueness and selectivity of the injector system with various injecting ways.
4.3.1 The unique inlet design solves the injecting discrimination, while the dual-column compensation function not only solve the problem of program drift by heating, and minus the effects of background noise, so as to get the minimum LOD.
4.3.2 Installed two kinds of injectors: packed column injector, split/splitless capillary injector(with the function of diaphragm cleaning). 


4.4 Good stability and high sensitivity of the detector and its perfect supporting facilities can satisfy your various detection requirements.
It is convenient and time-saving, while the injectors can get high sensitivity, precise results and less error by using FID, headspace injecting method and the special chromatographic column for ethylene oxide.
 
4.5 Improved column designation for precisely controlling the programmed heating and furnace temperature, with the features of stability, balance and time-saving.
4.5.1 Increased column volume, and the intelligent backdoor system largely shortens the time for detector to keep stable and balance after the programmed heating/cooling.
4.5.2 Heating furnace temperature ramp range: environmental temperature +5ºC~420ºC.
4.5.3 7 steps programmed heating and the heating rate is 0.1~120ºC/min.
4.5.4 You can re-calibrate the furnace temperature, and set the maximum temperature within 420ºC according to your needs for the balance time of the heating furnace temperature.


.Parameters
Column oven
Furnace dimensions 28 x 30 x 18cm
Temperature range Room temperature +5~420ºC
Temperature setting 1ËšC, programmed heating rate 0.1ËšC
Maximum heating speed 120ºC/min
Temperature stability it will be 0.01ËšC, when the environmental temperature changes 1ËšC.
Programmed heating 7 steps
Programmed heating rate 0.1-120ºC/min(increment of 0.1ºC)
Column loss can be compensated (dual channel column)
FID
Maximum operating temperature 400ºC
LOD ≤5 x 10-12g/s[n-C16]
Drift ≤5 x 10-13A/min
Noise ≤2 x 10-15A
Linear dynamic range ≥107

.Application fields
It is widely used in the fields of petroleum, chemical, food, pharmaceutical, environmental protection, disease control, safety supervision, water, electricity, metallurgy, scientific research and QC.

.Detail pictures
Gas Chromatography Analysis/ High Accuracy and Precision Lab Equipment Instrument

HD LCD screen display, clear and could protect the eyes
Gas Chromatography Analysis/ High Accuracy and Precision Lab Equipment Instrument
You
 can choose different detectors, for example FID/TCD/FPD/ECD/NPD
Gas Chromatography Analysis/ High Accuracy and Precision Lab Equipment Instrument


·
Packing&Shipping
(1)Standard export wooden case with high quality cushioning material ensure the item arrive customer in good condition.
(2)Carefully check every packing detail before delivery to avoid any troubles during the transportation.
(3)Appointed logistics company could be used according to customers demands.
(4)Do our best to make sure customer can get their goods in time.

Gas Chromatography Analysis/ High Accuracy and Precision Lab Equipment Instrument


·About Kejie Group
Nanjing Kejie Group have one researching institution and four professional production bases,which is a leading manufacturer in R&D, manufacturing and sales of gas chromatography, high efficient liquid chromatography, atomic absorption spectrometer, atomic fluorescence, UV visible spectrophotometer, headspace injector and other analytical instruments and related products.

Gas Chromatography Analysis/ High Accuracy and Precision Lab Equipment Instrument


·Our Service
Our commitment to you doesn't end when your equipment is shipped-It begins.
1,One years'warranty supported by product experts
2,AMC,post warranty,24H/7D response
3,Lifetime's spare parts supply for our products
4,Long term distribution partners worldwide ensure individual on-site customer consultation and service.

·Contact Information
Address:
2nd floor, A1 building, Nanjing University of Sci&Tech,
No.129-3 Guanghua Road, Nanjing City,
Jiangsu Province, China
Postal Code: 210014

.Sales Contact
Tel: 86-0731-84135155  
FAX: 86-0731-89833299
 
 

Please feel free to submit your inquiry information to us.We will contact with you as soon as possible.


·FAQ
Q1: Are you the factory?
A1: Of course we are,we have one Researching Institution and four Professional Production Bases
 
Q2:What's the warranty period? How do you provide this?
A2:Two years (24 month).
We have very strict inspection, the instruments which you received is high-quality and reliable.
If there's any error, we'll provide you the on line solution with in 12 hours. We'll provide you the spare parts and the shipping cost totally free.
If the problem was caused by the instrument quality, and cannot be repaired, we'll ship you the new one.
 
Q3:What's the production time?
A3:Usually 20 days for production, some equipment need extra time to debug.
 
Q4:What's the Dlivery method ?

A4:Light-weight cargo is usually by express , Air transport and sea shipping is acceptable (provide with safty packing)
 
Q5:What's the delivery time?
A5:According to different method and country , express will be 6~15 days
 
Q6:How to install and operate?
A6:According to each instruction manual which sent with equipment. ( We also provide after-sale technical support)
 
Q7:What's the payment term?
A7:Usually we do 50%TT deposit ,50%TT balance before shipping.Western Union, are acceptable.


 

Ambient Vaporizer Part: Finned tubes are the basic components of ambient vaporizer, pressure building vaporizer,

on which heat transfer to be finished depends. The Star-shape Fin Tube lined SS pipe , helicoil fin tube lined SS tubes, are also named Steel-Aluminum Composite Finned Tube.

Intercooler, Radiator Part: All kinds of tubes, flat tube, round tube, harmonica-shaped tube etc

Deep aluminum processing

We also provide the Bimetallic Extruded Fin Tube For Heat Exchanger,Fin Forming Machines,Aluminium Extruded Fin Tubes.

Ambient Vaporizer


Fin Tube

Spiral Fin Tube,Steel-Aluminum Composite Finned Tube,Aluminum Extruded Fin Tube with Lined SS Pipe,Intercooler Fin Tube,Bimetallic Extruded Fin Tube For Heat Exchanger,Fin Forming Machines,Aluminium Extruded Fin Tubes

Wuxi Better Technology Co., Ltd , https://www.btheatexchanger.com